VERIFICATION
OF INFILTRATION AT SEWER PIPE JOINTS
Jie Liu and C. Vipulanandan
Center
for Innovative Grouting Materials and Technology (CIGMAT)
Department of Civil and
Environmental Department
Tel: (713) 743-4291 E-mail Address: jliu5@bayou.uh.edu
Infiltration due
to leaking pipes, manholes, laterals and other components of a wastewater
system will add to the problem of overflow and substantially load the treatment
facilities. Frequent overflows not only lead to regulatory problems but also
increase the treatment cost. In order to quantify the infiltration at the
joints of the pipes, a full scale test facility has been developed to perform
hydrostatic tests for straight joints up to 7 psi. Also angular tests and shear
tests at the joints can be performed using this test facility. Preliminary
testing is underway on 30-in diameter sewer pipes. The testing protocol is
being reviewed by number of pipe associations.
Preliminary literature review indicates that each type of
sewer pipes is tested differently to determine the infiltration rate at the
pipe joint. Hence a testing protocol must be developed to better quantify the
infiltration at pipe joints under various joint-loading conditions. Based on
review of the literature and ASTM testing standards, a testing protocol for
determining the infiltration at the pipe-joint must be developed.
Since several factors in the field can
affect the performance of pipe joint, it is important to identify the important
factors through controlled experiments where important variable is studied one
at a time. In this project, a comprehensive testing program was developed to
determine the leak rate at pipe joints.
2. OBJECTIVE
The overall objective is to determine, through laboratory controlled testing, the infiltration leak-rates for different types of large diameter sewer pipe-joint under various loading conditions. The specific objectives are as follows:
1. Develop a testing protocol to determine the infiltration at the pipe-joint under the following conditions:
a. Straight joint (Method A)
b. Angular deflection (Method B)
c. Shear load (Method C)
Develop a testing facility to perform the tests under an external hydrostatic pressure.
3. TESTING PROGAM
Model A. Straight Pipe Joint Test
In order to stimulate the straight pipe-joint condition this model test (Fig. 1) is proposed using 30 in. diameter pipe. A composite watertight bladder was designed and used at the joint to apply the necessary water pressure for testing. The pipe manufacturer will submit a data sheet on the joint. Any preconditioning for the joint as recommend by the manufacture will be done before the test. Water pressure up to 7 psi will be applied. Infiltration will be collected from the pipe interior and quantified to an accuracy of 1 ml.
Model B. Angular
Deflection Test
In order to stimulate the angularity at the pipe-joint condition this model test (Fig. 1) is proposed using 30 in. diameter pipe. A composite water tight bladder will used at the joint to apply the necessary water pressure during the rotation of the joint.
Model C. Shear
Load/Deflection Test
In order to stimulate the shear loading at the pipe-joint condition this model test is proposed using 30 in. diameter pipe. A composite water tight bladder will used at the joint to apply the necessary water pressure during the shearing of the joint.
4. MEASUREMENTS
(i) Testing Parameters: Pressure and time used for the hydrostatic test will be noted. Applied shear load/deflection will be recorded.
(ii) Leak Rate: Joint will be subjected to hydrostatic pressure of 3, 4,5 6 and 7 psi and the leak rate will be determined. Pressures 3, 4,5 and 6 will be held 5 minutes and pressure 7 psi for 10 minutes.
(iii) Visual Inspection: After the test the joint will be carefully inspected for and defects.


(a) Rigid Pipe (b) Semi-rigid/Flexible Pipe
5. CONCLUSION
Testing facility can be used to qualify the infiltration rates at sewer pipe joints under various loading conditions.
6. ACKNOWLEDGEMENT:
The study was supported by CIGMAT under grant from U.S. EPA. Fiberglass Institute participation is very much appreciated.
7. REFERENCE
Annual Book of ASTM Standards (1999), Section 4 (Construction) and Section 8
(Plastics), ASTM, Philadelphia, PA.
If you have any questions, please contact Dr. C.Vipulanandan